Description: Failed 20-Inch Wastewater Force Main

Sanitary Sewer Force Main Evaluation And Replacement

Client: Town of Middletown

Sanitary Sewer Force Main Evaluation And Replacement

Location: Middletown, Rhode Island


• Assessment of 40 year old 20 inch ductile iron sewer force main including internal and external inspection and assessment
• Evaluate mode of failure and perform evaluation for best method of rehabilitation or replacement
• Design of 6300 linear feet of new 24 inch replacement force main including permitting requirements in coastal area and within State Highway
• Design included 12 MGD by-pass pumping system design
• Included design and permitting of major stream crossing
• Work completed under RIDEM Immediate Compliance Order